14 TROUBLESHOOTING: Scrub Head Circuit Breaker is Tripped WEAK CIRCUIT BREAKER The circuit breaker should not trip below its stated 30 Amp rating. Replace circuit breaker(s) if found weak and faulty. Part Number: E28954-00 Wait 5 minutes to reset circuit breakers TROUBLESHOOTING: GeneSys™ Machine will Not Drive CIRCUIT BREAKER MAY BE TRIPPED Inspect and reset circuit breaker. If problem persists replace circuit breaker. Wait 5 minutes to reset circuit breakers BATTERY METER IS FLASHING When the voltage level corresponding to the stopping threshold is reached, the last yellow LED will flash for 15 seconds, then the red LED will turn on, and the blocking relay will open. To reset, switch off the machine and charge the batteries and turn on the machine. Red LED should be off. When the battery level indicator is switched on the battery voltage is measured and in any case: 1. If the voltage is below the stopping threshold, instantaneous stopping will occur. 2. If the voltage is higher than the resting threshold, all the LED’s will turn on again and the battery level indicator will reset in order to start a new working cycle. 3. If the voltage ranges between the stopping threshold and the resetting threshold, the LED’s will turn on rapidly to the condition prior to the switching off. If the previous condition was a stop, the last yellow LED will flash. SPEED KNOB TURNED ALL THE WAY DOWN Check the speed controller on the console. Increase the speed setting to a comfortable walk. Faulty Wiring: Trace all wiring from transaxle to electrical enclosure. Then trace from the electrical enclosure up to the micro switches inside the console handle. Check for faulty wiring and poor or loose connections.